Premium Lock 210A

14" Panel Width

 

 

 

ALLOWABLE LOAD TABLES FOR PREMIUM PANELS, INC.
PREMIUM LOCK 210a STANDING SEAM PANEL

Width: 14.00 inch, Alloy: ASTM A792- G50, Gauge: 24

Allowable Strength Design (ASD)
Wind Load Factor = 1.0
Allowable Uniform Load (psf)
 

 

Span
Deflection
Span Length (Feet)
 
2.00
2.25
2.50
2.75
3.00
3.25
3.50
3.75
4.00
1
L/180
230
204
183
167
148
126
108
94
83
L/240
230
204
183
167
148
126
108
94
83
L/360
230
204
183
167
148
126
108
94
83
2
L/180
287
245
201
167
148
126
108
94
83
L/240
287
245
201
167
148
126
108
94
83
L/360
287
245
201
167
148
126
108
94
83
3
L/180
287
255
230
193
164
140
121
106
94
L/240
287
255
230
193
164
140
121
106
94
L/360
287
255
230
193
164
140
121
106
94

 

 

Span
Deflection
Span Length (Feet)
 
4.25
4.50
4.75
5.00
5.25
5.50
5.75
6.00
6.25
1
L/180
73
65
58
52
47
43
39
36
33
L/240
73
65
58
52
47
43
39
36
33
L/360
73
65
58
52
47
43
39
36
33
2
L/180
73
66
58
52
47
43
39
36
33
L/240
73
65
58
52
47
43
39
36
33
L/360
73
65
58
52
47
43
39
36
33
3
L/180
83
74
67
60
54
50
42
36
38
L/240
83
74
67
60
54
50
42
36
38
L/360
83
74
67
60
54
50
42
36
38

 

 

Span
Deflection
Span Length (Feet)
 
6.50
6.75
7.00
7.25
7.50
7.75
8.00
8.25
8.50
1
L/180
30
28
26
24
23
21
20
18
17
L/240
30
28
26
24
23
21
20
18
17
L/360
30
27
24
22
20
18
16
15
13
2
L/180
30
28
26
24
23
21
20
18
17
L/240
30
28
26
24
23
21
20
18
17
L/360
30
28
26
24
23
21
20
18
17
3
L/180
35
33
30
28
26
24
23
21
20
L/240
35
33
30
28
26
24
23
21
20
L/360
35
33
30
28
26
24
23
21
20

 

 

Span
Deflection
Span Length (Feet)
 
8.75
9.00
9.25
9.50
9.75
10.00
10.25
10.50
10.75
1
L/180
16
15
14
13
13
12
11
11
10
L/240
16
15
14
13
13
12
11
11
10
L/360
12
11
10
10
9
8
8
7
7
2
L/180
16
15
14
13
13
12
11
11
10
L/240
16
15
14
13
13
12
11
11
10
L/360
16
15
14
13
13
12
11
10
9
3
L/180
19
18
17
16
15
14
13
13
12
L/240
19
18
17
16
15
14
13
13
12
L/360
19
18
17
16
15
14
13
13
12

 

1. The formula's in Load Tables for EXPOSURE and DEFLECTION are:
One Span - Mp= .125wl^2, Mn= .125wl^2, x= .0130wl^4/EI
Two Span - Mp= .125wl^2, Mn= .096wl^2, x= .0092wl^4/EI
Three Span - Mp= .080wl^2, Mn= .107wl^2, x= .0069wl^4/EI
Modulas of Elasticity (E) = 29,500 ksi

2. Allowable uniform loads are determined per the following:
a) Allowable Shear Stress (FV) [AISI c3.2]
b) Combined Bending and Shear [AISI c3.3]
c) Combined Bending and Web Crippling [AISI c3.5]

3. Factors of Safety used to determine uniform loads:
W (Bending) = 1.67
W (Shear) = 1.67
W (Web Crippling) = 1.85

4. Allowances have been made for member Dead Weight.

5. Minimum panel support bearing length = 2.00 in

6. Concentrated load = 150 lb at mid-span, load width = 4 in
Simple Span : Max. Span = 8.302ft (L/180)
Two Span : Max. Span = 9.786ft (L/180)
Three Span : Max. Span = 10.025ft (L/180)

 

 

Copper Roof

 

Call us today!

Phone 303-420-8538

Fax 303-420-8356


Hours

Mon - Thurs 7:00 - 4:00

Friday 7:00 - 12:30


 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cool metal roofing, metal, flat stock, coil, metal coil, aluminum coil, steel coil, coolr, sheffield, sheffield metals, drexel, drexel metals, gutters, sheet metal, coil metal, steel, englert, metalsales, metal sales, soffit, corrugated, standing seam, steel soffit, soffit panel, aluminum soffit, vented soffit, perforated soffit, 80003, denver, colorado, denver colorado, arizona, longmont, boulder, evergreen, summit county, boulder county, weld county, wind uplift, cortez, colorado springs, castle rock, jefferson county, grand junction, grand mesa, roof panels, roofing, flashing, corrugated, pro panel, classic rib, exposed fastener, screws, clips, UL clips, rubber grommet screws, berridge, berridge panels, gutter, half round gutter, cold roll, painted, painted gutter, prefinished gutter, 

 

 

 

Contact Us