Premium Lock 210A

12" Panel Width

 

 

 

ALLOWABLE LOAD TABLES FOR PREMIUM PANELS, INC.
PREMIUM LOCK 210a STANDING SEAM PANEL

Width: 12.00 inch, Alloy: ASTM A792- G50, Gauge: 24

Allowable Strength Design (ASD)
Wind Load Factor = 1.0
Allowable Uniform Load (psf)

 

Span
Deflection
Span Length (Feet)
 
2.00
2.25
2.50
2.75
3.00
3.25
3.50
3.75
4.00
1
L/180
268
238
214
195
173
147
126
110
96
L/240
268
238
214
195
173
147
126
110
96
L/360
268
238
214
195
173
147
126
110
96
2
L/180
336
286
234
195
173
147
126
110
96
L/240
336
286
234
195
173
147
126
110
96
L/360
336
286
234
195
173
147
126
110
96
3
L/180
336
298
268
225
191
163
142
124
109
L/240
336
298
268
225
191
163
142
124
109
L/360
336
298
268
225
191
163
142
124
109

 

 

Span
Deflection
Span Length (Feet)
 
4.25
4.50
4.75
5.00
5.25
5.50
5.75
6.00
6.25
1
L/180
85
76
68
61
55
50
46
42
39
L/240
85
76
68
61
55
50
46
42
39
L/360
85
76
68
61
55
50
46
42
38
2
L/180
85
76
68
61
55
50
46
42
39
L/240
85
76
68
61
55
50
46
42
39
L/360
85
76
68
61
55
50
46
42
39
3
L/180
97
86
78
70
64
58
53
49
45
L/240
97
86
78
70
64
58
53
49
45
L/360
97
86
78
70
64
58
53
49
45

 

 

Span
Deflection
Span Length (Feet)
 
6.50
6.75
7.00
7.25
7.50
7.75
8.00
8.25
8.50
1
L/180
36
33
30
28
26
25
23
22
20
L/240
36
33
30
28
26
25
23
22
20
L/360
34
30
27
25
22
20
18
17
15
2
L/180
36
33
30
28
26
25
23
22
20
L/240
36
33
30
28
26
25
23
22
20
L/360
36
33
30
28
26
25
23
22
20
3
L/180
41
38
35
33
31
29
27
25
24
L/240
41
38
35
33
31
29
27
25
24
L/360
41
38
35
33
31
29
27
25
24

 

 

Span
Deflection
Span Length (Feet)
 
8.75
9.00
9.25
9.50
9.75
10.00
10.25
10.50
10.75
1
L/180
19
18
17
16
15
14
13
13
12
L/240
19
18
17
16
15
14
13
12
11
L/360
14
13
12
11
10
9
9
8
8
2
L/180
19
18
17
16
15
14
13
13
12
L/240
19
18
17
16
15
14
13
13
12
L/360
19
18
17
15
14
13
12
11
11
3
L/180
22
21
20
19
18
17
16
15
14
L/240
22
21
20
19
18
17
16
15
14
L/360
22
21
20
19
18
17
16
15
14

 

1. The formula's in Load Tables for EXPOSURE and DEFLECTION are:
One Span - Mp= .125wl^2, Mn= .125wl^2, x= .0130wl^4/EI
Two Span - Mp= .125wl^2, Mn= .096wl^2, x= .0092wl^4/EI
Three Span - Mp= .080wl^2, Mn= .107wl^2, x= .0069wl^4/EI
Modulas of Elasticity (E) = 29,500 ksi

2. Allowable uniform loads are determined per the following:
a) Allowable Shear Stress (FV) [AISI c3.2]
b) Combined Bending and Shear [AISI c3.3]
c) Combined Bending and Web Crippling [AISI c3.5]

3. Factors of Safety used to determine uniform loads:
W (Bending) = 1.67
W (Shear) = 1.67
W (Web Crippling) = 1.85

4. Allowances have been made for member Dead Weight.

5. Minimum panel support bearing length = 2.00 in

6. Concentrated load = 150 lb at mid-span, load width = 4 in
Simple Span : Max. Span = 8.666 ft (L/180)
Two Span : Max. Span = 10.411 ft (L/180)
Three Span : Max. Span = 10.666 ft (L/180)

 

 

Copper Roof

 

Call us today!

Phone 303-420-8538

Fax 303-420-8356


Hours

Mon - Thurs 7:00 - 4:00

Friday 7:00 - 12:30


 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cool metal roofing, metal, flat stock, coil, metal coil, aluminum coil, steel coil, coolr, sheffield, sheffield metals, drexel, drexel metals, gutters, sheet metal, coil metal, steel, englert, metalsales, metal sales, soffit, corrugated, standing seam, steel soffit, soffit panel, aluminum soffit, vented soffit, perforated soffit, 80003, denver, colorado, denver colorado, arizona, longmont, boulder, evergreen, summit county, boulder county, weld county, wind uplift, cortez, colorado springs, castle rock, jefferson county, grand junction, grand mesa, roof panels, roofing, flashing, corrugated, pro panel, classic rib, exposed fastener, screws, clips, UL clips, rubber grommet screws, berridge, berridge panels, gutter, half round gutter, cold roll, painted, painted gutter, prefinished gutter, 

 

 

 