Premium Lock 200

16" Panel Width

 

 

ALLOWABLE LOAD TABLES FOR PREMIUM PANELS, INC.
PREMIUM LOCK 200 STANDING SEAM PANEL

Width: 16.00 inch, Alloy: ASTM A792- G50, Gauge: 24

Allowable Strength Design (ASD)
Wind Load Factor = 1.0
Allowable Uniform Load (psf)

 

Span
Deflection
Span Length (Feet)
 
2.00
2.25
2.50
2.75
3.00
3.25
3.50
3.75
4.00
1
L/180
201
178
160
146
132
112
96
84
74
L/240
201
178
160
146
132
112
96
84
74
L/360
201
178
160
146
132
112
96
84
74
2
L/180
251
218
179
149
132
112
96
84
74
L/240
251
218
179
149
132
112
96
84
74
L/360
251
218
179
149
132
112
96
84
74
3
L/180
251
223
201
172
145
125
108
94
83
L/240
251
223
201
172
145
125
108
94
83
L/360
251
223
201
172
145
125
108
94
83

 

 

Span
Deflection
Span Length (Feet)
 
4.25
4.50
4.75
5.00
5.25
5.50
5.75
6.00
6.25
1
L/180
65
58
52
47
42
38
35
32
29
L/240
65
58
52
47
42
38
35
32
29
L/360
65
58
52
47
42
38
35
32
28
2
L/180
65
58
52
47
42
38
35
32
29
L/240
65
58
52
47
42
38
35
32
29
L/360
65
58
52
47
42
38
35
32
29
3
L/180
74
66
59
53
48
44
40
37
34
L/240
74
66
59
53
48
44
40
37
34
L/360
74
66
59
53
48
44
40
37
34

 

 

Span
Deflection
Span Length (Feet)
 
8.75
9.00
9.25
9.50
9.75
10.00
10.25
10.50
10.75
1
L/180
14
13
13
12
11
11
10
10
9
L/240
12
13
13
12
11
10
10
9
8
L/360
10
9
9
8
7
7
6
6
6
2
L/180
14
13
13
12
11
11
10
10
9
L/240
14
13
13
12
11
11
10
10
9
L/360
14
13
12
11
11
10
9
8
8
3
L/180
17
16
15
14
13
13
12
11
11
L/240
17
16
15
14
13
13
12
11
11
L/360
17
16
15
14
13
13
12
11
10

 

1. The formula's in Load Tables for EXPOSURE and DEFLECTION are:
One Span - Mp= .125wl^2, Mn= .125wl^2, x= .0130wl^4/EI
Two Span - Mp= .125wl^2, Mn= .096wl^2, x= .0092wl^4/EI
Three Span - Mp= .080wl^2, Mn= .107wl^2, x= .0069wl^4/EI
Modulas of Elasticity (E) = 29,500 ksi

2. Allowable uniform loads are determined per the following:
a) Allowable Shear Stress (FV) [AISI c3.2]
b) Combined Bending and Shear [AISI c3.3]
c) Combined Bending and Web Crippling [AISI c3.5]

3. Factors of Safety used to determine uniform loads:
W (Bending) = 1.67
W (Shear) = 1.67
W (Web Crippling) = 1.85

4. Allowances have been made for member Dead Weight.

5. Minimum panel support bearing length = 2.00 in

6. Concentrated load = 150 lb at mid-span, load width = 4 in
Simple Span : Max. Span = 7.179 ft (L/180)
Two Span : Max. Span = 8.715 ft (L/180)
Three Span : Max. Span = 9.152 ft (L/180)

 

 

Copper Roof

 

Call us today!

Phone 303-420-8538

Fax 303-420-8356


Hours

Mon - Thurs 7:00 - 4:00

Friday 7:00 - 12:30


 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cool metal roofing, metal, flat stock, coil, metal coil, aluminum coil, steel coil, coolr, sheffield, sheffield metals, drexel, drexel metals, gutters, sheet metal, coil metal, steel, englert, metalsales, metal sales, soffit, corrugated, standing seam, steel soffit, soffit panel, aluminum soffit, vented soffit, perforated soffit, 80003, denver, colorado, denver colorado, arizona, longmont, boulder, evergreen, summit county, boulder county, weld county, wind uplift, cortez, colorado springs, castle rock, jefferson county, grand junction, grand mesa, roof panels, roofing, flashing, corrugated, pro panel, classic rib, exposed fastener, screws, clips, UL clips, rubber grommet screws, berridge, berridge panels, gutter, half round gutter, cold roll, painted, painted gutter, prefinished gutter, 

 

 

 