Premium Lock 200

14" Panel Width

 

 


ALLOWABLE LOAD TABLES FOR PREMIUM PANELS, INC.
PREMIUM LOCK 200 STANDING SEAM PANEL

Width: 14.00 inch, Alloy: ASTM A792- G50, Gauge: 24

Allowable Strength Design (ASD)
Wind Load Factor = 1.0
Allowable Uniform Load (psf)

 

Span
Deflection
Span Length (Feet)
 
2.00
2.25
2.50
2.75
3.00
3.25
3.50
3.75
4.00
1
L/180
230
204
183
167
151
128
110
96
84
L/240
230
204
183
167
151
128
110
96
84
L/360
230
204
214
167
151
128
110
96
84
2
L/180
287
249
204
170
151
128
110
96
84
L/240
287
249
204
170
151
128
110
96
84
L/360
287
249
204
170
151
128
110
96
84
3
L/180
287
255
230
196
166
142
123
108
95
L/240
287
255
230
196
166
142
123
108
95
L/360
286
255
230
196
166
142
123
108
95

 

Span
Deflection
Span Length (Feet)
 
4.25
4.50
4.75
5.00
5.25
5.50
5.75
6.00
6.25
1
L/180
74
66
59
53
48
44
40
37
34
L/240
74
66
59
53
48
44
40
37
34
L/360
74
66
59
53
48
44
40
37
32
2
L/180
74
66
59
53
48
44
40
37
34
L/240
74
66
59
53
48
44
40
37
34
L/360
74
66
59
53
48
44
40
37
34
3
L/180
84
75
68
61
55
50
46
42
39
L/240
84
75
68
61
55
50
46
42
39
L/360
84
75
68
61
55
50
46
42
39

 

Span
Deflection
Span Length (Feet)
 
6.50
6.75
7.00
7.25
7.50
7.75
8.00
8.25
8.50
1
L/180
31
29
27
25
23
21
20
19
18
L/240
31
29
27
25
23
21
20
19
18
L/360
28
25
23
20
18
17
15
14
13
2
L/180
31
29
27
25
23
21
20
19
18
L/240
31
29
27
25
23
21
20
19
18
L/360
31
29
27
25
23
21
20
19
18
3
L/180
36
33
31
29
27
25
23
22
21
L/240
36
33
31
29
27
25
23
22
21
L/360
36
33
31
28
27
25
23
22
21

 

Span
Deflection
Span Length (Feet)
 
8.75
9.00
9.25
9.50
9.75
10.00
10.25
10.50
10.75
1
L/180
16
15
15
14
13
12
12
11
10
L/240
16
15
15
14
12
12
11
10
9
L/360
12
11
10
9
8
8
7
7
6
2
L/180
16
15
15
14
13
12
12
11
10
L/240
16
15
15
14
13
12
12
11
10
L/360
16
15
14
13
12
11
10
9
9
3
L/180
19
18
17
16
15
14
14
13
12
L/240
19
18
17
16
15
14
14
13
12
L/360
19
18
17
16
15
14
14
13
12

 

1. The formula's in Load Tables for EXPOSURE and DEFLECTION are:
One Span - Mp= .125wl^2, Mn= .125wl^2, x= .0130wl^4/EI
Two Span - Mp= .125wl^2, Mn= .096wl^2, x= .0092wl^4/EI
Three Span - Mp= .080wl^2, Mn= .107wl^2, x= .0069wl^4/EI
Modulas of Elasticity (E) = 29,500 ksi

2. Allowable uniform loads are determined per the following:
a) Allowable Shear Stress (FV) [AISI c3.2]
b) Combined Bending and Shear [AISI c3.3]
c) Combined Bending and Web Crippling [AISI c3.5]

3. Factors of Safety used to determine uniform loads:
W (Bending) = 1.67
W (Shear) = 1.67
W (Web Crippling) = 1.85

4. Allowances have been made for member Dead Weight.

5. Minimum panel support bearing length = 2.00 in

6. Concentrated load = 150 lb at mid-span, load width = 4 in
Simple Span : Max. Span = 7.184 ft (L/180)
Two Span : Max. Span = 8.721 ft (L/180)
Three Span : Max. Span = 9.406 ft (L/180)

 

 

 

Copper Roof

 

Call us today!

Phone 303-420-8538

Fax 303-420-8356


Hours

Mon - Thurs 7:00 - 4:00

Friday 7:00 - 12:30


 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cool metal roofing, metal, flat stock, coil, metal coil, aluminum coil, steel coil, coolr, sheffield, sheffield metals, drexel, drexel metals, gutters, sheet metal, coil metal, steel, englert, metalsales, metal sales, soffit, corrugated, standing seam, steel soffit, soffit panel, aluminum soffit, vented soffit, perforated soffit, 80003, denver, colorado, denver colorado, arizona, longmont, boulder, evergreen, summit county, boulder county, weld county, wind uplift, cortez, colorado springs, castle rock, jefferson county, grand junction, grand mesa, roof panels, roofing, flashing, corrugated, pro panel, classic rib, exposed fastener, screws, clips, UL clips, rubber grommet screws, berridge, berridge panels, gutter, half round gutter, cold roll, painted, painted gutter, prefinished gutter, 

 

 

 

 

 